Multiple Phi2


280 repeats of Phi2 measurements (Orange LED) with 10 min delay between measurements

[
  {
    "pulses": [
      20,
      20,
      50,
      20
    ],
    "environmental": [
      [
        "light_intensity",
        0
      ],
      [
        "temperature",
        0
      ],
      [
        "relative_humidity",
        0
      ]
    ],
    "protocols_delay": 4,
    "get_offset": 1,
    "get_ir_baseline": [
      15,
      14
    ],
    "pulsesize": 10,
    "measurements": 280,
    "pulsedistance": 10000,
    "act1_lights": [
      0,
      0,
      20,
      0
    ],
    "act_intensities": [
      0,
      0,
      692,
      0
    ],
    "cal_intensities": [
      4095,
      0,
      0,
      0
    ],
    "meas_intensities": [
      0,
      560,
      560,
      560
    ],
    "detectors": [
      [
        34
      ],
      [
        34
      ],
      [
        34
      ],
      [
        34
      ]
    ],
    "meas_lights": [
      [
        14
      ],
      [
        15
      ],
      [
        15
      ],
      [
        15
      ]
    ],
    "measurements_delay": 600
  }
]