GrainspeQ-All-in-one-CZ


This protocol is used with the GrainspeQ device. It starts by measuring electronic offset followed by PAM fluorescence (Green measuring, Blue Actinic), spectrally resolved UV excited fluorescence, and 340nm-780nm color-reflectance. Use with the GrainspeQ device only please.

[
  {
    "pulses": [
      200,
      1,
      400,
      400,
      400,
      1,
      1,
      1,
      1,
      1,
      1,
      1
    ],
    "averages": 1,
    "averages_delay": 0,
    "get_ir_baseline": [
      15,
      14
    ],
    "pulsesize": 10,
    "pulsedistance": 1000,
    "act1_lights": [
      0,
      0,
      16,
      16,
      16,
      15,
      15,
      15,
      14,
      14,
      14,
      14
    ],
    "act_intensities": [
      0,
      0,
      1000,
      1000,
      1000,
      0,
      0,
      0,
      0,
      0,
      0,
      0
    ],
    "cal_intensities": [
      0,
      0,
      500,
      4000,
      0,
      0,
      4095,
      0,
      3000,
      3000,
      3000,
      3000
    ],
    "meas_intensities": [
      0,
      0,
      500,
      4000,
      0,
      2000,
      2000,
      2000,
      0,
      0,
      0,
      0
    ],
    "detectors": [
      [
        34
      ],
      [
        0
      ],
      [
        34
      ],
      [
        34
      ],
      [
        34
      ],
      [
        0
      ],
      [
        0
      ],
      [
        0
      ],
      [
        0
      ],
      [
        0
      ],
      [
        0
      ],
      [
        0
      ]
    ],
    "meas_lights": [
      [
        13
      ],
      [
        13
      ],
      [
        20
      ],
      [
        20
      ],
      [
        20
      ],
      [
        13
      ],
      [
        13
      ],
      [
        13
      ],
      [
        13
      ],
      [
        13
      ],
      [
        13
      ],
      [
        13
      ]
    ],
    "spec": [
      0,
      1,
      0,
      0,
      0,
      1,
      1,
      1,
      1,
      1,
      1,
      1
    ],
    "intTime": [
      0,
      500,
      0,
      0,
      0,
      50,
      100,
      200,
      379.6,
      569.5,
      854,
      1281
    ],
    "delay_time": [
      1,
      1,
      1,
      1,
      1,
      1,
      1,
      1,
      1,
      1,
      1,
      1
    ],
    "read_time": [
      35,
      35,
      35,
      35,
      35,
      35,
      35,
      35,
      35,
      35,
      35,
      35
    ],
    "accumulateMode": [
      0,
      0,
      0,
      0,
      0,
      0,
      0,
      0,
      0,
      0,
      0,
      0
    ]
  }
]
Dave in cap img 4615
Created by

David M. Kramer


Category

Miscellaneous
Connected Macro

Return Raw Trace


Compatible Instruments

CoralspeQ


Latest Update

Sep 2018