Fluorescence and reflectance with PAR-test2-AK2


Fluorescence measurement with 450 nm for actinic, followed by taking spectra with 405 nm and 535 nm, and reflectance measurement using white and 405 nm LEDs simultaneously. Integration time for the reflectance measurement are 100, 200 and 400.

[
  {
    "_protocol_set_": [
      {
        "pulses": [
          1
        ],
        "pulse_distance": [
          200
        ],
        "pulse_length": [
          [
            10
          ]
        ],
        "pulsed_lights": [
          [
            1
          ]
        ],
        "pulsed_lights_brightness": [
          [
            0
          ]
        ],
        "nonpulsed_lights": [
          [
            1
          ]
        ],
        "nonpulsed_lights_brightness": [
          [
            500
          ]
        ],
        "detectors": [
          [
            0
          ]
        ],
        "spec": [
          1
        ],
        "delay_time": [
          100
        ],
        "read_time": [
          35
        ],
        "intTime": [
          1
        ],
        "accumulateMode": [
          0
        ],
        "averages": 1
      },
      {
        "pulses": [
          1
        ],
        "pulse_distance": [
          200
        ],
        "pulse_length": [
          [
            10
          ]
        ],
        "pulsed_lights": [
          [
            1
          ]
        ],
        "pulsed_lights_brightness": [
          [
            0
          ]
        ],
        "nonpulsed_lights": [
          [
            1
          ]
        ],
        "nonpulsed_lights_brightness": [
          [
            500
          ]
        ],
        "detectors": [
          [
            0
          ]
        ],
        "spec": [
          1
        ],
        "delay_time": [
          100
        ],
        "read_time": [
          35
        ],
        "intTime": [
          10
        ],
        "accumulateMode": [
          0
        ],
        "averages": 1
      },
      {
        "pulses": [
          1
        ],
        "pulse_distance": [
          200
        ],
        "pulse_length": [
          [
            10
          ]
        ],
        "pulsed_lights": [
          [
            1
          ]
        ],
        "pulsed_lights_brightness": [
          [
            0
          ]
        ],
        "nonpulsed_lights": [
          [
            1
          ]
        ],
        "nonpulsed_lights_brightness": [
          [
            500
          ]
        ],
        "detectors": [
          [
            0
          ]
        ],
        "spec": [
          1
        ],
        "delay_time": [
          100
        ],
        "read_time": [
          35
        ],
        "intTime": [
          100
        ],
        "accumulateMode": [
          0
        ],
        "averages": 1
      },
      {
        "pulses": [
          1
        ],
        "pulse_distance": [
          200
        ],
        "pulse_length": [
          [
            10
          ]
        ],
        "pulsed_lights": [
          [
            1
          ]
        ],
        "pulsed_lights_brightness": [
          [
            0
          ]
        ],
        "nonpulsed_lights": [
          [
            1
          ]
        ],
        "nonpulsed_lights_brightness": [
          [
            500
          ]
        ],
        "detectors": [
          [
            0
          ]
        ],
        "spec": [
          1
        ],
        "delay_time": [
          100
        ],
        "read_time": [
          35
        ],
        "intTime": [
          1000
        ],
        "accumulateMode": [
          0
        ],
        "averages": 1
      }
    ]
  }
]
Img 20161024 131107688 hdr
Created by

Christopher


Category

Algae
Connected Macro

HyperspeQ4s


Compatible Instruments

CoralspeQ


Latest Update

Dec 2017